Common Pitfalls Of Retrofit Window Installations Are:
Improper Or Missing Penetration Flashings
Flashing manufacturers typically require between 4 and 9 inches on the face of the wall, making it nearly impossible to around the window.
applications.
We have observed many buildings damaged because
Installers May Not Consider Design Pressure Ratings
location all factor into the design pressure rating for a pressure ratings are often higher than accounted for by windows not being able to withstand the wind and design pressure rating for the building).
Installers Typically Do Not Provide Trickle Vents
One of the simplest ways to provide passive fresh air intake to a home is through trickle vents installed into
Installers Often Do Not Pull Permits
Besides being a legal requirement, pulling a permit for a window replacement project has
project where the building enclosure is a common element). Permit requirements mandate a code information for the proposed window. While pulling a permit does not ensure a code compliant installation, it certainly requires the installer to demonstrate an understanding and intent to meet code requirements.
Warranties
It is unlikely that a problem will manifest, to the point of being visible to the owner, within
Another warranty consideration is that of the siding or cladding system is likely to void cladding installation and/or material warranties.
So…How Do Associations Avoid This Nightmare? The following Best Practices are a good place to start:
Windows should be the association’s responsibility, NOT the individual owners (but always check your governing documents). This policy protects the association from potential liability of the building enclosure being compromised by individual owners’ contractors.
Require prior approval for ANY penetrations through the building enclosure. Similar to a permit application, the review process will not ensure compliance, but does force the contractor to communicate the details of the proposed installation. It also provides an opportunity for a building enclosure professional to review the proposed installation and make recommendations as applicable.
Contractors specializing in multi-family building enclosure construction understand the liability involved for the association (and for themselves). installation.
the installation provides assurance to all parties (association, unit owner and contractor) that newly installed components have been appropriately integrated with the existing building enclosure.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32