“It is far safer and less costly to prevent an electrical problem than it is to repair one.”


TEGG Corp


Following are a few components that you should consider when implementing your electrical preventive maintenance program:


ARID-Ice scores ™


with a fog, condensation, mold and drip free environment for over 400 NHL,Triple A, Double A, Collegiate, Recreational Ice Rinks and Curling Clubs Across North America.


These facilities benefit from ARID-Ice desiccant dehumidification for full capacity enhanced humidity control while maintaining automatic indoor air quality.


ARID-Ice by Controlled Dehumidification has provided humidity and indoor air quality control technology to the Pittsburgh Penguins, New Jersey Devils, Jacksonville Barracudas, Florida Panthers, Houston Aero’s, University of Notre Dame and Penn State University just to name a few.


Contact our application specialists to learn how your arena can benefit from ARID-Ice technology. Call 810-229-7900 today.


Controlled Dehumidification ctrdh.com


• Visual/Mechanical Inspection: Visually inspecting your electrical components for cleanliness, proper alignment, moisture, dust, corrosion, and foreign objects can prevent unplanned issues. In addition, you can verify that electrical components are installed accurately, properly rated, and reduce or eliminate potential code violations.


• Infrared Termography Inspection: While under load, scanning your electrical components with an infrared camera can reveal heat differentials that could ultimately lead to failure and even a fire. In addition, these “hot spots” are areas of energy waste and will spike your utility bill.


• Ultrasonic Testing: Just as infrared thermography converts colors that we can’t normally see to colors that we can see, ultrasonic testing converts sounds that we can’t normally hear to sounds that we can hear. Ultrasonic testing can detect minor arcing and tracking, mechanical looseness, destructive corona, “chattering” between contacts and insulation deterioration.


• Voltage & Current Testing: Taking diagnostic measurements will help you dig down to the root cause of the perceived issue. With the proper testing equipment, you’re able to check for voltage and current imbalances, voltage drop, harmonic distortions and power quality issues, to name a few. Tese measurements will provide the root cause of a perceived issue and be your base for trending and tracking purposes.


Infrared inspection reveals a


significant heat signature on the A phase of this individual disconnect.


18


ISI EDGE SPRING 2017


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44